Oil-immerced power transformer S11-M-100/10 Three phase 30kva-2500kva

Oil-Immersed Power Transformer

Oil-immerced power transformer S11-M-100/10 Three phase 30kva-2500kva

Oil-immersed transformer is based on oil as the main insulation means of transformer, and relies on oil as the cooling medium, such as oil-immersed self-cooling, oil-immersed air cooling, oil-immersed water cooling and forced oil circulation. The main components of the transformer are iron core, winding, fuel tank, oil pillow, breathing apparatus, explosion-proof tube (pressure relief valve), radiator, insulation sleeve, tap changer, gas relay, thermometer, oil purifier and so on.

    Product featureHeg


    Due to oil's abillity to permeate between the layers of oil-immersed transformer silicon steel and its elastic buffering properties from prolonged immersion in the transformer, oil-immersed transformer noise is minimal.The Laminated Core Type Transformer has a high fill factor,an inscribed polygon cross section,and a multistage step lapped joint fully oblique structure that can reduce noise and magnetic resistance. After stress is eliminated by high tempreture annealing,no-load loss is significantly decreased.

    product detailsHeg

    The over signal ought to be installed,and the transformer is capable of operating in both normal and accidental overload scenarios.In the event that installing the overload signal is not possible,a thorough measuring device ought to be present.

     

    The oil-immersed transformer's overload signal value ought to be between 1.1 and 1.2 times its rated current.Depending on the current of the fan when it is operating,the dry transformer's overload signal value should be between 1.2 and 1.3 times its rated current.

     

    When the transformer overload signal is activated,it is important to monitor changes inthe load and temperature of the transformer.Additionally,the reason of the overload should be promptly inspected and ivestigated when conditions allow.There is a lot of overload overload-more than 1.3 times the rated current) or the temperature exceeds the upper limit should be reduced load.

    Performance parameter table(Oil-immersed Power Transformer)Heg

    Model

    Rated Capacity (KVA)

    Join Group Label

    Voltage Combination(KV)

    No Load

    Losses (W)

    Load Losses

    (W)

    No Load Current (%)

    Impedance (%)

    HV

    Tapping Range

    LV

    S11-M-30

    30

    Yyn0    OR      Dyn11

    6    6.3

    10

    10.5

    11

    ±5%

    OR

    ±2×2.5%

     

    0.4

    100

    600

    2.3

    4

    S11-M-50

    50

    130

    870

    2

    S11-M-63

    63

    150

    1040

    1.9

    S11-M-80

    80

    180

    1250

    1.9

    S11-M-100

    100

    200

    1500

    1.8

    S11-M-125

    125

    240

    1800

    1.7

    S11-M-160

    160

    280

    2200

    1.6

    S11-M-200

    200

    340

    2600

    1.5

    S11-M-250

    250

    400

    3050

    1.4

    S11-M-315

    315

    480

    3650

    1.4

    S11-M-400

    400

    570

    4300

    1.3

    S11-M-500

    500

    680

    5100

    1.2

    S11-M-630

    630

    810

    6200

    1.1

    4.5

    S11-M-800

    800

    980

    7500

    1

    S11-M-1000

    1000

    1150

    10300

    1

    S11-M-1250

    1250

    1360

    12800

    0.9

    S11-M-1600

    1600

    1640

    14500

    0.8

    S11-M-2000

    2000

    2280

    17820

    0.6

    5

    S11-M-2500

    2500

    2700

    20700

    0.6


      